NO | PARTS | DESCRIPTION |
1 | Panel: | Tempered Galss with metal housing, customised logo is available on the glass. |
2 | Panel Size: | 750*430MM |
3 | Bottom Body: | Galvanized |
4 | Left Burner: | 165MM big size infrared burner. |
5 | Right Burner: | 165MM big size infrared burner. |
6 | Pan Support: | Enamal Grill with fire board. |
7 | Water Tray: | SS |
8 | Ignition: | Battery 1 x 1.5V DC |
9 | Gas Pipe: | Aluminum Gas pipe, Rotary connector. |
10 | Knob: | Metal |
11 | Packing: | Brown box, with left+right+upper foam protection. |
12 | Gas Type: | LPG or NG. |
13 | Product Size: | 750*430MM |
14 | Carton Size: | 790*475*205MM |
15 | Cutout Size: | 640*350MM |
16 | Loading QTY: | 400PCS/20GP, 900PCS/40HQ |
Metal knob
Tempered Galss with metal housing
165MM big size infrared burner.Save more than 30% gas
What measures should be taken when using liquefied petroleum gas for cooking fires? The normal flame of LPG gas cooker products is light blue, the flame inside is clear, with a height of about 20mm, a slight noise and strong firepower; If the flame is very small, its causes and troubleshooting methods The troubleshooting method is as follows 1. Improper position of discharge terminal and bracket 2. Adjust the ignition needle spark to keep it above the fire cover hole 3. Whether the cylinder valve is open - normally open 4. The pulse igniter is broken, and the battery power is insufficient - replace the pulse or battery 5. The spark of igniter is weak or there is sound during ignition without spark 6. Increase the ignition distance by more than or equal to 4-6 mm Replace the pulse or battery 7. Burner damper is too small - adjust